MethodsThe activity measurement procedure for gamma emitting radionuclides in counting samples with the use of gamma radiation spectrometers and SpectraLine and Nuclide Master Plus softwareThe activity measurement procedure for gamma emitting radionuclides with energy from 50 to 3000 keV in the counting samples of laboratory geometries in the range from 1 to 106 Bq with the use of gamma-radiation spectrometers with SpectraLine and Nuclide Master Plus software has been developed by LSRM and detailed in the document "The activity measurement procedure for gamma emitting radionuclides in counting samples with the use of gamma radiation spectrometers and SpectraLine and Nuclide Master Plus software". It has been certified under national standards.
The measurement procedure for randomly distributed activity of gamma-emitting radionuclides in casks using a gamma-spectrometric system with SpectraLine softwareThe measurement procedure for randomly distributed activity has been developed by LSRM and detailed in the document «The measurement procedure for randomly distributed activity of gamma-emitting radionuclides in casks using a gamma-spectrometric system with SpectraLine software». It has been certified under the national standard GOST 8.638-2013.
The method of measurement of the specific activity of radionuclides in the counting samples by beta-spectrometers using SpectraLine softwareThe method of measurement of the specific activity of radionuclides in the counting samples by beta-spectrometers using SpectraLine software has been developed by LSRM and detailed in the document «Radionuclides activity in the counting samples. The method of measurement by beta-spectrometers using SpectraLine software». It has been certified under the national standard GOST R 8.594. The signed copy of the certificate:
Please, send the scan of user certificate of SpectraLine to lsrm@lsrm.ru to get the copy of the method in electronic format. The method of measurement of the specific activity of radionuclides in the counting samples by gamma-spectrometers using SpectraLine softwareThe method of measurement of the specific activity of radionuclides in the counting samples by gamma-spectrometers using SpectraLine software has been developed by LSRM and detailed in the document «Radionuclides activity in the counting samples. The method of measurement by gamma-spectrometers using SpectraLine software». It has been certified under the under the national standard GOST R 8.594. The signed copy of the certificate:
Please, send the scan of user certificate of SpectraLine to lsrm@lsrm.ru to get the copy of the method in electronic format. The procedure of measuring the activity of gamma-emitting radionuclides in containers with wastes, using a gamma-spectrometric system with software "LSRM" - SpectraLine and EffMakerThe procedure of measuring the activity of gamma-emitting radionuclides in containers with wastes, using a gamma-spectrometric system with software "LSRM" - SpectraLine and EffMaker has been developed by LSRM and FGUP VNIIFTRI. It is detailed in the document «Procedure of measuring the activity of gamma-emitting radionuclides in containers with wastes, using a gamma-spectrometric system with software "LSRM" - SpectraLine and EffMaker» and has passed the metrological certification under the national standards GOST R 8.563 and GOST R 8.594.
On the basis of the performed operations (experimental measurements and theoretical calculations) for the specification of the range of measurement of the specific activity the following correction should be done in the text of the Procedure:
As the Procedure is designed to measure containers of different masses, including NRSC with a mass of up to 10 ton,
The method of measurement of the activity of radionuclides in the counting samples by alpha-spectrometers using SpectraLine softwareThe method of measurement of the activity of radionuclides in the counting samples by alpha-spectrometers using SpectraLine software has been developed by LSRM and Department of Radiochemistry of Faculty of Chemistry of Moscow State University, and detailed in the document "The method of measurement of the activity of radionuclides in the counting samples by alpha-spectrometers using SpectraLine software". It has been certified under the under the national standard GOST R 8.563-2009.
|
The method "Dose rate. Methodology of calculation on the base of gamma-spectrum" (PDF, 647 ÊÁ) |
The method «High loading operation. The method of failures treatment» (PDF, 194 ÊÁ) |
The method of measurements using portable semiconductor and scintillation gamma-spectrometers (JPEG, 185 ÊÁ) |
|
© ÎÎÎ «ËÑÐÌ», 1997—2023 | Developed in NEOR, 2008 |